Hot air regenerative dryer: Do you know how to maintain a hot air dryer?


Hangzhou Shenbang Purification Equipment Co., Ltd. mainly deals in various compressed air after-treatment equipment, including modular dryers, zero-air-consumption dryers, hot-air regeneration dryers, combined dryers, combined dryers (manufacturer wholesale), waste-heat regeneration dryers, compression heat dryers, adsorption dryers, refrigeration dryers, precision filters, and other equipment.

  1. For a heatless regenerative blower dryer, clean or replace the filter element of the compressed air pipeline filter once a month, and replace it regularly thereafter. Clean the dryer exhaust silencer; if the pressure in the regeneration tower of the regeneration cycle is greater than or equal to 0.035 MPa, replace the silencer.

  2. Every three months, briefly close the pressure reducing valve and check for leaks in the air intake pneumatic valve. If air is discharged from the exhaust silencer, it indicates a leak.

  3. No lubricants are required in the heatless regenerative blower dryer.

  Daily inspection: Check the automatic drain valve on the pre-filter every shift.

 Heatless Regenerative Blower Dryer

  Weekly inspection:

  1. Check if the tower switching, regeneration, and pressurization of the heatless regenerative adsorption dryer are functioning normally.

  2. Check operating conditions, inlet pressure, inlet temperature, and air flow.

  3. Check if the regeneration silencer of the heatless regenerative dryer is clogged. If the regeneration pressure of the regeneration tower is too high, it indicates that the silencer needs to be replaced.

  4. Check the pressure drop of the pre-filter and post-filter. If the pressure drop exceeds 0.07 MPa, replace the filter element.

  Monthly inspection:

  Check the control air filter pressure reducing valve filter element and replace it as needed.

  Quarterly inspection:

  1. Check the pre-filter and post-filter cores for clogging and possible damage, and replace them as needed.

  2. Close the inlet/outlet valves or bypass the dryer to depressurize the heatless regenerative adsorption dryer system, open the desiccant filling port, and take a sample to check the desiccant. If the desiccant is contaminated with oil and pulverized, replace the desiccant.

  3. Remove and inspect the air intake pneumatic valve and regeneration exhaust valve, clean and replace worn valve seats and seals.

  4. Check the pneumatic valve cylinders of the heatless regenerative dryer for leaks or worn seals.

  5. Check the check valve and repair or replace it as needed.

  6. Check and maintain the control air solenoid valve.

  7. Calibrate the dew point probe (if equipped with a dew point meter).

  8. Check if the silencer of the heatless regenerative dryer is clogged with oil or dust. If the back pressure exceeds 0.035 MPa, it should be replaced.

  9. Please use accessories specifically designed for heatless regenerative adsorption dryers to avoid unnecessary losses.

Freeze dryer, forced air regeneration dryer, combined dryer manufacturer wholesale

Zhejiang Cnrison Tech Co,. Ltd

The company has a stable team of high-quality talents, professional design and development team, modern technical equipment, advanced production technology, perfect testing equipment. Technical transformation and innovation can be carried out according to the special requirements of customers in order to meet the development needs of the market.

online message

Contact Us

Company Phone:0571-64533786
Electronic E-mail:libin1357@126.com
Company Fax:0571-64533777
Company headquarters: jiande city daci rock town industrial functional area

Mobile

Mobile browsing

Copyright©2023 Hangzhou Shenbang Purification Equipment Co., Ltd. All Rights Reserved

Business License